Abstract
IntroductionApproximately 700,000 patients per year, in the United States, are afflicted with vertebral compression fracture (VCF) secondary to osteoporosis. 1 , 2 , 3 , 4 The lifetime risks of symptomatic vertebral compression fracture (VCF) secondary to osteoporosis is 16% for females, and 5% for males. Osteoporotic VCF survival rate, five years after diagnosis made, is 61%. VCF affects 25% of females over the age of 50 and 40% of females over the age of 80 1 , 2 , 3 , 4 . VCF is defined as the reduction of vertebral body (VB) height by 15% or greater and can be classified by the degree and type of deformity, which includes wedge, biconcavity, and compression fractures. 3 The most commonly compressed VB levels are lower thoracic vertebrae, L1 and L4. 3 Of course, there is also post-traumatic type of VCF and other types of pathology causing VCF. Traditional conservative treatment of vertebral body compression fracture includes analgesics, immobilization, muscle relaxant, physiotherapy, and external bracing, if indicated. 3 The resulting painful collapse and kyphosis leads to the development of chronic pain syndrome in one-third of these patients. 4 In greater than 50% of osteoporotic patients with more than one VCF, activities of daily living cannot be performed without assistance. 5 The resulting spinal deformity from VCF is the increased risk factor for hip fracture, cardio pulmonary complication, and physical debilitation from inactivity. 1 , 2 , 3 , 6 , 7 , 8 , 9 , 10 Many other potential consequences are obvious with chronic severe pain, decreased lung function, inactivity, severe anxiety, and depression with 23% increase in mortality rate. 1 , 2 , 3 , 10 , 14 >The goals of vertebral augmentation are; correction of VB deformity, significant reduction of pain, improvement of quality of life, to improve ability to perform daily living activities and to lower complication rate, e.g., hip fracture, cardio pulmonary complication and physical debilitation from inactivity, subsequent adjacent VCF and reduced mortality rate. 1 , 2 , 3 , 10 Historically, vertebroplasty and kyphoplasty have provided excellent pain relief for VCF, but with very high incidence of complication, i.e., leakage of Polymethylmethacrylate (PMMA) into spinal canal or vasculature, cardiopulmonary complication, and adjacent vertebral fracture. Therefore, vertebral augmentation (VA) is indicated for painful VCF. 1 , 2 , 3 A percutaneous vertebral augmentation system with a polyethylene mesh sac (OptiMesh® Spineology, Inc., Stillwater, MN) and morcelized bone graft, is designed, developed and used for VCF treatment without above complications, and is a true biologic vertebral reconstruction. This provides excellent pain relief and fewer technological risks and is osteoconductive and osteoinductive. With accumulated surgical experience in percutaneous endoscopic minimally invasive spinal surgery, this vertebral augmentation procedure can be easily performed percutaneously with minimal or no blood loss, for vertebral body reconstruction, for excellent pain relief, and to improve quality of life. 11 , 12 , 13 IndicationsTreatment criteria for this polyethylene mesh sac and morcelized bone graft (OptiMesh®) percutaneous vertebral augmentation system are:
Absolute contra-indication in the following situations
Relative contra-indication in the following situations
Operating Room Set UpBoth local anesthesia (under IV conscious sedation) and general anesthesia can be used. It is Author's preference to use local anesthesia with IV conscious sedation for a single level, and general anesthesia for multiple levels. Patient Positioning (Fig. 1a, b, c):In prone as for thoracic or lumbar surgery on a radiolucent Jackson table or a Kambin frame. Digital C-arm fluoroscopy with image intensifier is to be utilized for monitoring of the procedure for radiographic visualization of the position and surgical instrumentation. The patient is prepped and draped in the usual sterile fashion.
Figure 1: Patient positioning Surgical TechniqueImplant Device (Fig. 2):A polyethylene mesh sac (OptiMesh®) consists of three dimension multi-strand polyester mesh or sac to be packed with bony allograft inside the polyethylene mesh with specially ground bone chips or morcelized bone chips inside the mesh sac device creating a hyperdensed graft pack for restoring height resulting in pain relief.
Figure 2: Polyethylene mesh sac (OptiMesh™) and 2nd sac packed with bone chips Granular MechanicsGranules flow like liquid when uncontained but act like solid when contained. The granular packs are known to be porous even in their most rigid state. Surgical ProceduresInstruments and Preparation: Surgical instruments are demonstrated in the illustrations.The procedure is performed under fluoroscopic guidance with a guide pin to the desired target position as “50/50 image” on AP and lateral view of the spinal vertebra. Usually, the stylette or the guide pin starts approximately 5-10cm from mid-line (thoracic 5-7cm and lumbar 8-10cm) para-pedicularly (Fig. 3a), approximately 45° angle to contact the superior lateral quadrant of the pedicle and vertebral body junction. The portal of entry is extrapedicular approach (Fig. 3 b,c), with stylette inserted just lateral and superior to the pedicle on the lateral view, centered within the pedicle although anatomically it would be lateral to it. On the PA view the needle should appear to enter the bone at the superior lateral aspect of the vertebral body with a trajectory aiming inferomedially, approximately 20 degrees towards the spine process, and toward the desired target position as “50/50 image” on AP view (Fig. 4a). On the lateral view, the trajectory is directed toward the anterior inferior aspect of the vertebral body and toward the desired target position as “50/50 image” on lateral view (Fig. 4b). The spinal cord is less at risk with a more lateral starting position than the transpedicle approach, especially at the thoracic spine region. Lateral deviation risks pneumothorax. Also lateral vertebral body violation can injure the segmental artery, great vessels or lungs.
Figure 3: Portal of entry and trajectory for the guide pin for desired position “50/50 image”
Figure 4: Guide pin trajectory toward and beyond desired target position of “50/50 image” (red dot) under fluoroscopy A dilator is inserted over the guide pin and impacted into the vertebra (Fig. 5 a,b). Then a working channel or cannula (access portal) is placed over the dilator and secured to the metal frame connected to the operating table (Fig. 6a,b,c).
Figure 5: Dilator of the guide pin impacted onto the vertebra
Figure 6: Working cannula placed over the dilator After removal of the guide pin and dilator, a drill was utilized to create a cavity in the vertebra (Fig. 7a,b,c).
Figure 7: Drilling the vertebra The polyethylene mesh sac (OptiMesh®) size is based on the anticipated height, drill depth, and the cavity created by the shaper (Fig. 8a), after drilling to insure good fit for the cavity created and mesh pore distension (Fig. 8b).
Figure 8: Shaper The polyethylene mesh sac is inserted through the working channel (access portal) into the vertebral cavity (Fig. 9 a, b). Then the mesh is filled with morcelized bone graft from diverted fill tubes (Fig. 10 a, b, c, d, e).
Figure 9: Mesh sac is inserted through the working channel (access portal) into the vertebral cavity
Figure 10: Filling the OptiMesh® with morcelized bone graft (implant) After compacting the mesh with the bone chips, the neck of the mesh sac is crimped (Fig. 11 a,b). The instruments are removed and the wound is closed.
Figure 11: The mesh sac is crimped at the neck and is detached, before the instruments are removed. Vertebral Augmentation Procedure: Illustrations step-by-step (Fig. 12a-f)
Figure 12: Vertebral augmentation procedure – illustrations step by step Step 1 (Fig. 12a) Insert the guide pin Step 2 (Fig. 12b) Access portal over dilator Step 3 (Fig. 12c) Cavity is enlarged with shaper Step 4 (Fig. 12d) Insert OptiMesh® implant or mesh sac Step 5 (Fig. 12e) OptiMesh® filled with morcelized bone graft Step 6 (Fig. 12f) OptiMesh® is detached Case IllustrationsCase 1 (Fig. 13a-e) is a 70 year old male with severe thoracolumbar pain on activity from T10 post-traumatic osteoporotic vertebral compression fracture. Under conscious sedation and local anesthesia, OptiMesh® vertebral augmentation was performed as an outpatient. The patient had immediate excellent postoperative pain relief (VAS scores) and was discharged from the surgical unit in two hours.
Figure 13: 70 year old male with severe thoracolumbar pain on activity from T10 osteoporotic post-traumatic vertebral compression fracture (VCF). Case 2 (Fig. 14a-d) is a 72 year old female with severe thoracolumbar pain from T12 post-traumatic osteoporotic vertebral compression fracture. IV conscious sedation and local anesthesia were utilized for OptiMesh® vertebral augmentation with immediate significant postoperative pain relief right after the outpatient surgery and was discharged from the surgical unit in one hour.
Figure 14: 72 year old female with severe thoracolumbar pain from T12 post traumatic osteoporotic vertebral compression fracture (VCF). Case 3 (Fig. 15a-e) is a 71 year old female manager with painful post-traumatic osteoporotic compressive T7 fracture. As an outpatient under IV conscious sedation and local anesthesia, OptiMesh® vertebral augmentation was performed. She had immediate postoperative almost complete pain relief (VAS) and returned to work in three days. Seven weeks after surgery her CT scan demonstrated the evidence of osteointegration of the bone graft at T7 vertebra.
Figure 15: 70 year old female manager with painful post-traumatic osteoporotic wedge T7 vertebral compression fracture (VCF) DiscussionPainful osteoporotic fractures significantly reduce quality of life and are a significant risk factor for hip fracture, for secondary pulmonary insufficiency, physical disability from inactivity and increased mortality among the VCF patients. 8 , 10 The economic burden related to management of the osteoporotic VCF has been estimated to be $700 million per year. 9 While success in producing pain relief has been reported by many authors using PMMA techniques, numerous problems have developed. There is a risk of leakage into the disc or paraspinal region, into spinal neural foramen and spinal canal causing secondary significant neurological complications necessitating immediate surgery. 16 Some have resulted in permanent neurological deficit in spite of immediate evacuation of PMMA. Interestingly, the incidence of compressive complication from cement leakage is higher with kyphoplasty than vertebroplasty, perhaps related to higher incidence of surgical pedicle fracture. Also, hypotension may be produced by absorption of PMMA occasionally from its cardiotoxic and arrhythmogenic properties. Deaths have been documented from these procedures 23 pulmonary embolism and fat embolism have also been reported. 23 , 24 Of course, incidence of adjacent level fracture from VCF is as high as 52% after vertebroplasty, 29% for kyphoplasty are significant. 7 , 8 , 9 , 10 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 Minimally invasive percutaneous vertebral augmentation with intravertebral polyethylene mesh sac (OptiMesh®) is a new fill material containment technology for use in the minimally invasive vertebral biologic reconstruction procedure. It consists of a polyethylene mesh sac that is introduced into the vertebral body and filled with morcelized bone allograft. Compaction of the allograft bone inside the OptiMesh® device creates a hyperdense graft pack capable of reducing the fracture and restoring height by realigning fracture fragments resulting in pain relief and functional improvement. Obvious advantages of percutaneous vertebral augmentation with an intravertebral polyethylene mesh sac (OptiMesh®) filled with morcelized bone graft, over vertebroplasty and kyphoplasty are numerous. It includes no risk of leakage of PMMA into the spinal canal causing neurological complication or into the vasculature system, with cardio-pulmonary complications including cardio-toxicity, arrhythmia, and pulmonary embolism, and even lower risk of fatty embolism, indication for broader spectrum of pathology and the prospect of bone fusion and integration of the prosthesis over time by using bone rather than PMMA. The physical properties of the bone graft more closely approximate those to the adjacent vertebral segment in density tend to avoid subsequent adjacent vertebral fracture. The bony construct is also osteo-conductive and osteo-inductive to accomplish biologic vertebral reconstruction. It can be used to treat painful spinal hemangioma, other osteolytic vertebral lesions and other types of VCFs. Conclusion
References1. Garfin S, Reiley M, Wong W, et al., Vertebroplasty and Kyphoplasty. In: Savitz MH, Chiu JC, Yeung AD, eds. The Practice of Minimally Invasive Spinal Technique. Richmond, VA: AAMISMS Education, LLC; 2000: pp 249-260 2. Bono C, Garfin S, Kyphoplasty. In Kim D, Fessler R, Regan J, eds. New York: Thieme Medical Publisher; December 2004: Chapter 30, pp 328-337. 3. Do HM, Kim B, Percutaneous Vertebroplasty for Painful Vertebral Body Compression Fractures Endoscopic Spine Surgery and Instrumentation. In Kim D, Fessler R, Regan J, eds. New York: Thieme Medical Publisher; December 2004: Chapter 29, pp 315-327 4. Riggs BL, Melton U III. The worldwide problem of osteoporosis. Insights afforded by epidemiology. Bone 17:505S - 511S 5. Leidig-Bruckner G, Minne HW, Schlaich C, et al. Clinical grading of spinal osteoporosis: quality of life components and spinal deformity in women with chronic low back pain and women with vertebral osteoporosis. J Bone Miner Res 12:663-675, 1997 6. Yuan H, Brown C, Phillips F, Osteoporotic Spinal Deformity: A Biomechanical Rationale for the Clinical Consequences and Treatment of Vertebral Body Compression Fractures, J Spinal Disord Tech 17:236-242, 2004 7. Leech JA, Dulberg C, Kellie S et al. Relationship of lung function to severity of osteoporosis in women. Am Rev Respir Dis 141:68-71, 1990 8. Schlaich C, Minne HW, Bruckner T et al. Vertebral fractures and mortality in older women; a prospective study. Study of Osteoporotic Fractures Research Group. Arch Intern Med 159:1215-1220, 1998 9. Mefton LJ, III. Epidemiology of spinal osteoporosis. Spine 22:2S-11S, 1997 10. Fribourg D, Tang C, Sra P, et al. Incidence of subsequent vertebral fracture after kyphoplasty- Spine 29:2270-2276. 2004 11. Chiu J, Digital Technology Assisted Minimally Invasive Spinal Surgery (MISS) for Spinal Motion Preservation. In: Lemke H.U, Vannier MN, Invamura RD, eds. Computer Assisted Radiology and Surgery. Amsterdam, San Diego, Oxford, London; Elsevier Medical Publisher; 2004, pp 461-466. 12. Chiu, J., Posterolateral Endoscopic Thoracic Discectomy. In Kim D, Fessler R, Regan J, eds. Endoscopic Spine Surgery and Instrumentation. New York: Thieme Medical Publisher; December 2004: Chapter 11 pp 125-136. 13. Chiu, J., Endoscopic Lumbar Foraminoplasty In Kim D, Fessler R, Regan J, eds. Endoscopic Spine Surgery and Instrumentation. New York: Thieme Medical Publisher; December 2004: Chapter 19, pp 212-229. 14. Lindsay R, Silverman SL, Cooper C, et al. Risk of new vertebral fracture in the year following a fracture, JAMA 285:319-323, 2001 15. Gailbert P. Deramond H, Rosat P et al. Note preliminaire sur le traitment des angiomes vertebraux par vertebroplastie percutanee. Neurochinirgie 33: 166-168, 1987 16. Peters K, Guiot B, Martin P, et al. Vertebroplasty for osteoporotic compression fractures: current practice and evolving techniques. Neurosurgery 51: S2-96-S2-103, 2002 17. Convery F, Gunn D, Hugues D, et al. The relative safety of polymethylmethacrylate, J Bone Joint Surg Am 57A:57-64, 1975 18. Hasrop J, Prpa B, Reinhardt MK et al. Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplasty. Spine 29:2120-2125, 2004 19. Grados F, Depriester C, Cayrolle G, et al. Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. Rheumatology 39:1410- 1414, 2000 20. Silverman SL, Minshall ME, Harper KD et al. The relationship of health-related quality of life to prevalent and incident vertebral fractures in post-menopausal women with osteoporosis. Arthrisit Rheurn 44:2611-2619, 2001 21. Hyde JA, Feinberg J. Secondary osteoporotic compression fractures after kyphoplasty. Paper presented at 70th Annual Meeting of the American Academy of Orthopedic Surgeons; February 5-9,2003 New Orleans, LA 22. Phillips H, Cole PV, Lenin AW. Cardiovascular effects of implanted acrylic bone cement. Br Med 33:460-471, 1971 23. Nussbaum DA, Gailloud P, Kieeran M. A review of complications associated with vertebroplasty and kyphoplasty as reported to the Food and Drug Administration Medical Device Related Website. J Vasc Interv Radiol 15:1185-1192,2004 24. Aebli N, Krebs J, Davis G, et al. Fat embolism and acute hypotension during vertebroplasty. An experimental study in sheep. Spine 27:460-466, 2002